Temperature Transmitters
Product Details · PRODUCT DETAILS
LU-S510 Intelligent Temperature Transmitter
The LU-S510 intelligent temperature transmitter (round card) accepts RTD and thermocouple input and provides a two-wire 4-20mA analog transmission output. It is installed inside the sensor.
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111
I. Overview
The LU-S510 smart temperature transmitter (round card) is used for RTD and thermocouple (TC) signal input and provides a two-wire 4~20mA analog transmitter output; it is installed inside the sensor.
Core features:
Supports 8 thermocouple types and 2 RTD types, selectable through software configuration.
Custom temperature range, freely configurable in software.
In the event of a sensor fault (open/short circuit), the output exceeds the current range to indicate an alarm.
II. Technical Parameters
Input parameters
Input signal: RTD, thermocouple (TC)
Thermocouple cold junction compensation: switchable
Cold junction compensation range: -25~+65°C
Cold junction compensation accuracy: ±1°C
Output parameters
Output signal: 4~20mA
Output load: RL⩽(Ue−9)/0.021
Output current for upper/lower limit overflow and open/short circuit alarm: IL=3.85mA, IH=21mA
Power supply range: DC9~35V
Other parameters
Accuracy: class 0.075 by default; class 0.05 (LU-SU510B) or class 0.03 (LU-SU510C) available on request; class 0.15 by default for Cu50
Temperature drift: 0.02% FS/°C
Response time: 1 s to reach 90% of the final value
Operating temperature: -25~+65°C
EMC: complies with the requirements of GB/T18268 for industrial equipment applications (IEC 61326-1)
III. Input Types and Accuracy
Table Sensor model Type Measurement range Accuracy RTD Pt100 -200~850°C 0.075% RTD Cu50 -50~150°C 0.15% Thermocouple (Tc) S -50~1768°C 0.075% Thermocouple (Tc) R -50~1768°C 0.075% Thermocouple (Tc) B 250~1820°C 0.075% Thermocouple (Tc) K -270~1372°C 0.075% Thermocouple (Tc) N -200~1300°C 0.075% Thermocouple (Tc) E -270~1000°C 0.075% Thermocouple (Tc) J -210~1200°C 0.075% Thermocouple (Tc) T -270~400°C 0.075%
Note:
The above performance is tested at an ambient temperature of 20°C±2°C.
For thermocouple measurement, the cold junction error of ≤±1°C must be added.
LU-S510 Intelligent Temperature Transmitter User Manual
Click to download the product manual. If the download fails, please contact customer service.
RELATED PRODUCTS
View Related Products
Related Products
Need technical specifications and a quotation for this product?
Submit your request and our engineers will contact you within one business day.