Industrial Automation Instruments

Industrial automation instruments

Industrial Automation Instruments

LU-G12 Analog Signal Isolation Processor/Distributor (1 In / 2 Out) Isolators / Distributors

LU-G12 Analog Signal Isolation Processor/Distributor (1 In / 2 Out)

The LU-G12 one-input, two-output analog voltage/current signal isolator and distributor connects field two-wire transmitters, DC voltage sources and DC current sources, isolating and converting their 4-20mA/1-5V analog signals and distributing them over two channels to control systems or other modular instruments. It uses an independent DC supply with isolation between power supply, input and output.

View Details
LU-B11 Operation-End (Signal Output) Isolation Safety Barrier (1 In / 1 Out) Safety Barriers

LU-B11 Operation-End (Signal Output) Isolation Safety Barrier (1 In / 1 Out)

The LU-B11 operation-end (signal output) isolation safety barrier connects a variety of DC signals below 20mA or 10V. It receives DC voltage signals from a DCS/PLC system or other operator in the safe area, transmits them through the isolated barrier, and outputs the required DC current or voltage signal to drive I/P converters, valve positioners, display devices and other intrinsically safe instruments in the hazardous field. An independent power supply provides isolation between supply, input

View Details
JKH-D3 Intelligent Three-Phase SCR Phase-Shift Trigger/Voltage Regulator SCR Phase-shift Triggers

JKH-D3 Intelligent Three-Phase SCR Phase-Shift Trigger/Voltage Regulator

The JKH-D3 intelligent three-phase SCR phase-shift trigger/voltage regulator uses advanced microprocessor technology based on the LU-906 intelligent controller, with multiple built-in input specifications, dual digital display plus bar graph, and keypad operation. It suits constant-voltage or constant-current charging, electroplating, electrolysis and DC motor speed control. Wiring is simple with no phase sequence concerns, and reliable overcurrent protection prevents controller damage even if t

View Details
LU-50K Flow Totalizer Controllers & Temperature Controllers

LU-50K Flow Totalizer

The LU-50K flow totalizer is suitable for measuring the flow of various liquids, gases and steam, with pressure-based compensation and multiple input modes. It is designed for use with orifice plate flow meters.

View Details
LU-R6000 Distributed Paperless Recorder Paperless Recorders

LU-R6000 Distributed Paperless Recorder

The LU-R6000 is a distributed paperless recording system designed by Anthone Electronics. This high-performance data acquisition and logging platform is suited to analyzing, recording and controlling data under a wide range of conditions, and supports web-based access to acquired and recorded data.

View Details
Anthone DCS Distributed Control System Anthone DCS Distributed Control System

Anthone DCS Distributed Control System

The Anthone DCS distributed control system, composed of Anthone intelligent instruments and a host computer, features centralized management and decentralized control. Control and data acquisition are handled by the lower-level units, while the host computer monitors the entire process in real time and records and prints historical data. Because control is distributed, a host computer failure does not affect the lower-level units and faults do not spread between them, greatly reducing the chance

View Details
Small, Medium and Large Electric Furnace Control Cabinet Series Electric Furnace Control Cabinets

Small, Medium and Large Electric Furnace Control Cabinet Series

Anthone electric furnace control cabinets are built on Anthone instruments with standardized design, fine workmanship and complete functions. The press-formed, powder-coated cabinet body is attractive and uses imported key components. Cabinets can be designed and built to customer requirements in high, medium and low configurations. The 1-5KW small single-phase control box measures 260x105x200mm (W x H x D), with 220VAC supply and 1-5KW rated power.

View Details
LU-S14520 Isolated RS232 to RS485 Converter Module LU-S14000 Series I/O Modules

LU-S14520 Isolated RS232 to RS485 Converter Module

LU-S14520 Isolated RS232 to RS485 Converter Module

The LU-S14520 is an isolated RS232-to-RS485 converter providing 3000VDC isolation protection. It handles 485 bus control automatically, supports multiple baud rates with auto-detection, and offers transmission rates up to 115.2 kbps. The bus includes transient interference suppression and lightning protection. Highlights include strong EMC immunity: air discharge +/-12KV and contact discharge +/-6KV.

View Details
LU-CDP/GP Remote Flange Diaphragm Differential Pressure and Pressure Transmitter Pressure Transmitters / Controllers

LU-CDP/GP Remote Flange Diaphragm Differential Pressure and Pressure Transmitter

Output: 4-20mA DC. Span and zero: adjustable externally. Power supply: 24V DC; without load the transmitter can operate from 12V DC, up to 45V DC. Relative humidity: 0-100%. Electrical connection: NPT 1/2 internal thread. Weight: 2.4 kg (excluding options).

View Details
LU-G11 Analog Signal Isolation Processor/Distributor (1 In / 1 Out) Isolators / Distributors

LU-G11 Analog Signal Isolation Processor/Distributor (1 In / 1 Out)

Single-input, single-output analog signal isolator and distributor.

View Details
LU-A11 Detection-End (Signal Input) Isolation Safety Barrier (1 In / 1 Out) Safety Barriers

LU-A11 Detection-End (Signal Input) Isolation Safety Barrier (1 In / 1 Out)

Transmitter power supply for thermocouple and RTD signals, with independent power supply.

View Details
JKH-D4 Intelligent Three-Phase SCR Phase-Shift Trigger/Voltage Regulator SCR Phase-shift Triggers

JKH-D4 Intelligent Three-Phase SCR Phase-Shift Trigger/Voltage Regulator

The JKH-D4 intelligent three-phase SCR phase-shift trigger/voltage regulator uses advanced microprocessor technology based on the LU-906 intelligent controller, with multiple built-in input specifications, dual digital display plus bar graph, and keypad operation. It suits constant-voltage or constant-current charging, electroplating, electrolysis and DC motor speed control. Wiring is simple with no phase sequence concerns, and reliable overcurrent protection prevents controller damage even if t

View Details