Controllers & Temperature Controllers

Product Details · PRODUCT DETAILS

LU-50Y/51Y Flow Totalizer

The LU-50Y/51Y flow totalizer accepts flow signals from vortex, turbine, electromagnetic, Roots and other sensors. The flow channel supports frequency and analog current signals, the pressure channel accepts analog current signals, and the temperature channel is compatible with RTDs, thermocouples and analog current signals.

  • CategoryControllers & Temperature Controllers
  • Model-
  • Views6961 views
  • Updated2026-03-26
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111

 The LU-50Y series flow totalizer and the LU-51Y series flow batch quantitative controller offer the following core features:

Accepts various flow sensor signals such as vortex, turbine, electromagnetic and Roots; the flow channel supports frequency and analog current signals, the pressure channel accepts analog current signals, and the temperature channel is compatible with RTDs, thermocouples and analog current signals.
Provides 24V power to transmitters, simplifying system design and reducing investment cost.
Fault-tolerant: when the temperature/pressure or density compensation signal is abnormal, the manually set value is automatically used for the calculation.
No potentiometers, coding switches or other adjustable components, resulting in higher shock resistance, stability and reliability, and it also provides extensive self-check and self-diagnosis functions.
Supports multiple communication modes and can form an energy metering network system with a host computer.
Performs high-accuracy compensation calculation for hot water, general gases, superheated steam, saturated steam and natural gas.
Provides daily/monthly/annual flow accumulation with permanent data retention after power failure; offers over-upper/upper/lower/over-lower limit alarms for instantaneous flow, temperature and pressure, and generates alarm records.
The LU-51YU quantitative controller supports batch control based on cumulative flow and can be operated by keys or external pushbuttons. It supports single-valve, large/small-valve and valve/pump batching, and allows the valve (pump) closing advance to be set.
 
Main technical specifications
 
Measurement accuracy: class 0.2 (±0.2% FS±1 digit)
Input signal
Flow: pulse greater than 2V (>4V high level, <1V low level), frequency 1-9.5kHz, 0-10mA/4-20mA current
Pressure: 0-10mA, 4-20mA current
Temperature: RTD, thermocouple, 0-10mA/4-20mA current
Output signal: 1 transmitter output (0-10mA/4-20mA settable), with user-definable transmitter parameter and range
Alarm output: up to 4 relay outputs (resistive 250VAC/0.8A)
Output power supply: DC24V/50mA transmitter supply
Communication interface: RS-232, RS-485, optoelectronic isolation
Display: 240*160 dot-matrix LCD
Data protection: data retained for ten years after power failure
Power supply: AC (85V-265V), DC24V optional (note when ordering); power consumption < 8W
Panel size: 96mm×96mm, 80mm×160mm
Operating environment: temperature -10~+60°C, humidity 0~80RH%
 
Dimensions and mounting dimensions
 
Type A: dimensions 969677mm, cutout dimension related to 92mm
Type Y: dimensions 45100111.7mm, cutout dimension related to 45mm
Type D: dimensions 1608077mm, cutout dimension related to 153mm

 

LU-50Y/51Y Flow Totalizer User Manual

Click to download the product manual. If the download fails, please contact customer service.

Download Now
RELATED PRODUCTS

Related Products

View Related Products

Need technical specifications and a quotation for this product?

Submit your request and our engineers will contact you within one business day.