Products > Industrial Intelligent Instruments > Pressure Transmitter > LU-CGP electrical capacity pressure transmitter

LU-CGP electrical capacity pressure transmitter

1.       technical performance

●       to subject: liquid, gas or vapour

●       range ability: 

LU-CGPS-1200

0-0.25-1.5KPa

LU-CGPS-1300

0-1.2-7.2Kpa

LU-CGPS-1400

0-6-36Kpa

LU-CGPS-1500

0-30-180Kpa

LU-CGPS-1600

0-160-1000Kpa

LU-CGPS-1700

0-400-2500KPa

LU-CGPS-1800

0-1600-10000Kpa

LU-CGPS-1900

0-4000-25000Kpa

LU-CGPS-1000

0-7000-40000Kpa

●       output: 4-20mA DC

●       power: 24VDC, it may be 12VDC if non-load, max. is 45VDC

●       load characteristic:

●       positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.

Max. positive transfer: 500% of the min. span.

Max. negative transfer: 600% of the min. span.

●       Temperature:

temperature of operating for amplifier: -25℃ ~ +90℃

temperature of operating for sensor:  -40℃ ~ +104℃

●       Relative humidity: 0~100%

●       Sensor capacity changes: <0.16cm3

●       Indicate meter (field): scale gauge length: 30mm,

grade: 2.5

●       Isolating explosion: ds Ⅱ BT5,   Intrinsically-safety: ia Ⅱ CT5

●       Span & Zero: external continually adjusted

●       Over-pressure: 0 (absolute pressure) –14Mpa, when range < 6Mpa;

0 (absolute pressure) –32Mpa, when range < 20Mpa;

0 (absolute pressure) –52Mpa, when range < 42Mpa;

      no damage for transmitter but may cause zero shift, suggest not to operate over-pressure, the max. pressure is 60Mpa for flange template.

●       Damp: continually adjusted when time constant is between 0.2~1.67 seconds.

●       Settling time: 2s,

 

2. performance index (note: test under the condition of none shift, max. range status of sensor, 316L stainless isolating diaphragm and other standard condition)

●       Accuracy: ±0.25% of the span, including the synthesize errors of linear,     change-difference and repeat.

●       Stability: ±0.25% of max. range (12 months)

 

●       Temperature affect:

zero error:±0.5% / 55℃,  zero & range errors:±1.0% / 55℃, when max. range;

zero error:±3.0% / 55℃,  zero & range errors:±3.5% / 55℃, when min. range;

        note: for type LU-CGPS-1200 (1300), temperature affect is double times of above

●        Over-pressure affect: ±0.25% of max. range (according to permitted over-loads for     different ranges)

●       vibration affect: ±0.05% / g of the max. range, when 200Hz, any axis up.

●       Power affect: <0.005%/V of output range

●       Load affect: none affect when voltage >12VDC input to the transmitter.

●       Mounting position affect: may cause zero error max. 0.24Kpa, but can be calibrated,   none affect for range

 

3. structure index:

●       Structure material: diaphragm: 316 stainless steel, hastelloy C, Monel alloy, Tantalum;

                 O ring: Fluorin rubber;

Flange & bolt: 316 stainless steel;

Fill oil: silicon oil;

Electric shell: low-Cu & aluminum alloy

Plating of electric shell: toast lacquer of amido, formyl, ethene & colophony;

●       pressure-lead connector:

flange NPT 1/4 (taper pipe screw thread), (this is the transmitter flange connection);

connection head screw thread NPT 1/2 (taper pipe screw thread), (selected);

integrated needle valve of welded conduit connector (selected)  

●       electric parts connector:

down-lead conduit NPT 1/2 line-through hole;

electric cable connector (selected)

explosion-proof connector (selected)

●       net weight: 2.4kg (exclude the selected parts)

 


  • LU-L proliferate silicon liquid-level transmitter

  • LU-K proliferate silicon pressure transmitter

  • LU-CDP/GP remote flange diaphragm differential-pressure transmitter