Products > Industrial Intelligent Instruments > Pressure Transmitter > LU-C Series Differential-Pressure/Pressure transmitter

LU-C Series Differential-Pressure/Pressure transmitter

 

1.       Brief introduction
LU-C series electric capacity type differential-pressure/pressure transmitters adopt world advanced, mature and reliable electric capacity sensors technology thereby with high efficacy, excellent performance, compact and firm structure, greatly favorable for users.
The intelligent types adopt CPU to enhance the nimbleness & function and communicate with HART protocol.
The high intelligent types adopt digital, multi-parameters sensors, the zero self-calibrated (keep for 8 years), with temperature sensor to real time temperature compensation and with display screen & communication programmable keyboard, convenient & facilitate.
 
2.       Model composition:
This diagram has specified Anthone LU-C series transmitter types configuration thereby users are easy to choose the need type.
3.       main characteristic:
       Super measuring performance to measure the pressure, differential-pressure, liquid-level and flux.
       Digit accuracy: ±0.1%
       Total accuracy: ±0.25%F.S
       Stability: 0.25%, 60 months
       Turndown ratio: 100:1
       Measuring rate: 0.2S
       Miniaturization (2.4Kg), all stainless steel flange, easy to install.
       Process connection is compatible to other products, realized best measuring result.
       It adopts sensor that with H alloy protection, realized excellent cold & hot stability.
       It adopts 16 bits computer intelligent transmitter.
       Standard 4~20mA, with digit signal based on HART communication protocol, remote operated & controlled.
       Support the technology upgrade of all lines on field and that based on field controlling.
 
4.       Performance test:
(test under the condition: zero based range, silicon oil, 316L stainless steel diaphragm, turndown ratio:1:1, digit micro-adjust value is equal to range set point value)
 
1)       Accuracy: digital signal:±0.1%;
micro range (1.5kPa):±0.2%;                
note: when turndown ratio less than 10:1, the accuracy±0.25%
2)       Environment temperature affect (28): turndown ratio 1:1 to 10:1: ±0.2%;             micro range (1.5kPa): ±0.5%;
 
3)       Static pressure affect (for differential-pressure transmitter):                                 zero error (can be eliminated under static pressure):                           ±0.2% / 6.9MPa (for static pressure 0~13.7MPa)                                        ±0.5% / 6.9MPa (for static pressure >13.7MPa )
Range accuracy: ±0.25% / 6.9MPa
 
4) Stability: 60 months, ±0.25% F.S, (when temperature change 28, static pressure max. 6.9MPa, turndown ratio 1:1 )
 
5) Installation affect: zero shift max. 250Pa (can be calibrated), none range affect;
 
6) Vibration affect (except micro range): <±0.1% F.S when add 15Hz~2000Hz to any axes which related to the pipes installation process conditions.
 
7) Power affect: <0.005%/V
 
8) Radio frequency disturbing affect: ±0.1% F.S (20~1000MHz, 1m distance)
9) Insulation strength and reverse protection: none fly arc phenomenon if 50Hz, 100Vpp between the positive & negative wire connection terminals and shell continue for one minute. None damage if 24VDC contrary connected.
 
10) Power: 12V-45V DC (standard is 24VDC, may be 12VDC when without load,≥16VDC if digit indicated meter head)
 
11) Temperature for operating: -20~ +85
 
12) Temperature for storage: -40~ +104
 
13) Relative humidity: 0~90%
 
14) net weight: 2.4kg (except selected parts);
height: 166mm; Hole for cable: NPT1/2 or M20×1.5
 
15) Pressure-lead connection: pressure-lead hole:1/4 NPT inner taper pipe thread;      
    pressure-lead screw: M10
×1.5, span 41.3mm   
    center distance: 54mm (for range code 2,3,4,5)
 
16) Isolating diaphragm: 316L, Hastelloy alloy C, Monel, Ta, Heavy metal diaphragm
 
17) Vent/ drain valve: 316L, Hastelloy alloy C, Monel,
 
18) Left & Right sensor flange: precise casting 316L, 304, Hastelloy alloy C, Monel,
 
19) Sensor filled liquid: silicon oil, inert liquid, glycerine, water
 
20) Total protection: IP67
 
21) Isolating-explosion & Intrinsic Safety Certificated:                                    
Intrinsically Safety “i”, in conformity with GB3836.4-83, Explosion-Proof grade EX ia CT5; Explosion-isolated “d”, in conformity with GB3836.2-83, Explosion-Proof grade EX ds BT5;

After-sale service Pre sales consultation

Login  |  Register  Please login to ask question!




  • LU-L proliferate silicon liquid-level transmitter

  • LU-K proliferate silicon pressure transmitter

  • LU-CDP/GP remote flange diaphragm differential-pressure transmitter